Selfpriming Regenerative Mini Monoblock Pump
SharpPower Water Pumps stand for its top quality, robustness, reliability and cost effectiveness. The Pumps run with maximum efficiency that satisfy the need of every customer in various ranges of applications. SharpPower Water Pumps has recorded a remarkable growth with commitment towards value creation for its customers and stress on Research & Development.
Models | Power | Pipe Size (mm) | Discharge in LPM | Total heads in metres | ||||||||||||
KW / HP | Suc x Del | 3 | 6 | 12 | 18 | 24 | 30 | 33 | 36 | 38 | 40 | 45 | 48 | 50 | ||
Smart Flow(AL/CI) | 0.37 / 0.5 | 25 x 25 | 34 | 29 | 23 | 17 | 14 | 8 | ||||||||
High Flow | 0.37 / 0.5 | 25 x 25 | 45 | 40 | 28 | 24 | 20 | 15 | ||||||||
Big Flow | 0.37 / 0.5 | 25 x 25 | 48 | 44 | 33 | 28 | 23 | 17 | 13 | 8 | ||||||
Big Flow Dlx | 0.75 / 1.0 | 25 x 25 | 55 | 51 | 35 | 30 | 24 | 19 | 16 | 12 | 10 | |||||
Mega Flow Dlx (AL/CI) | 0.75 / 1.0 | 25 x 25 | 61 | 57 | 37 | 32 | 26 | 20 | 18 | 16 | 14 | 12 | ||||
Mega Flow | 0.75 / 1.0 | 25 x 25 | 64 | 59 | 50 | 48 | 43 | 39 | 37 | 34 | 32 | 29 | 23 | 20 | 15 | |
Wonder Flow (AL/CI) | 0.75 / 1.0 | 25 x 25 | 44 | 37 | 31 | 22 | 19 | 15 | 12 | |||||||
Power Flow CI | 1.1 / 1.5 | 25 x 25 | 51 | 48 | 46 | 42 | 37 | 32 | 28 | 25 | 20 | 18 | 13 | 10 | ||
Magic Flow | 0.75 / 1.0 | 25 x 25 | 46 | 40 | 33 | 24 | 21 | 17 | 10 | 8 |
Horizontal Openwell Pump
They assist to maintain the optimum flow of water fluctuation in the water stream. These Horizontal Open Well Submersible Pumps are best for open well or tanks where there are wide fluctuations in water level.
Models | Power | Pipe Size (mm) | Discharge in LPM | Total head in metres | ||||||
KW / HP | 10 | 15 | 20 | 25 | 30 | 35 | ||||
Elite Flow | 0.37 / 0.5 | 25 | 110 | 78 | 27 | |||||
Quick Flow | 0.37 / 0.5 | 25 | 160 | 120 | 63 | 10 | ||||
Gentle Flow | 0.37 / 0.5 | 25 | 163 | 156 | 66 | 13 | ||||
Free Flow | 0.75 / 1.0 | 25 | 170 | 138 | 108 | 58 | ||||
Well Flow | 0.75 / 1.0 | 25 | 178 | 151 | 118 | 70 | ||||
Giant Flow | 1.10 / 1.5 | 25 | 208 | 190 | 170 | 153 | 97 | 52 |
Multistage Centrifugal Pump
Multistage pumps are defined as pumps in which the fluid flows through several impellers fitted in series. This type of pump is often used in power station applications, e.g. as a boiler feed pump and in industrial applications requiring high pressures.
Models | Power | Pipe Size (mm) | m³/h | 0 | 1.2 | 2.4 | 3.6 | 4.8 | 6 | 7.2 |
KW / HP | Suc x Del | i/min | 0 | 20 | 40 | 60 | 80 | 100 | 120 | |
Shower 50 | 0.37 / 0.50 | 25 x 25 | Head in Meter | 28 | 22 | 20 | 15 | 6 | ||
Shower 80 | 0.60 / 0.80 | 25 x 25 | 30 | 24 | 21 | 17 | 6 | |||
Shower 100 | 0.75 / 1.00 | 25 x 25 | 40 | 34 | 30 | 26 | 16 | 6 | ||
Shower 150 | 1.10 / 1.50 | 25 x 25 | 50 | 40 | 30 | 20 | 10 | 6 | ||
Shower 200 | 1.50 / 2.00 | 25 x 25 | 60 | 50 | 40 | 30 | 20 | 10 |
Pressure Booster Pump
Multistage pumps are defined as pumps in which the fluid flows through several impellers fitted in series. This type of pump is often used in power station applications, e.g. as a boiler feed pump and in industrial applications requiring high pressures.
Models | Power | Pipe Size (mm) | m³/h | 0 | 1.2 | 2.4 | 3.6 | 4.8 | 6 | 7.2 |
KW / HP | Suc x Del | i/min | 0 | 20 | 40 | 60 | 80 | 100 | 120 | |
Shower 50 | 0.37 / 0.50 | 25 x 25 | Head in Meter | 28 | 22 | 20 | 15 | 6 | ||
Shower 80 | 0.60 / 0.80 | 25 x 25 | 30 | 24 | 21 | 17 | 6 | |||
Shower 100 | 0.75 / 1.00 | 25 x 25 | 40 | 34 | 30 | 26 | 16 | 6 | ||
Shower 150 | 1.10 / 1.50 | 25 x 25 | 50 | 40 | 30 | 20 | 10 | 6 | ||
Shower 200 | 1.50 / 2.00 | 25 x 25 | 60 | 50 | 40 | 30 | 20 | 10 |
Drainage / Sewage Pump
Sewage pumps transport sewage and untreated waste water (e. g. raw waste water). They are most commonly used in municipal waste water treatment plants but also in buildings and private homes (also see Sewage lifting unit) which cannot be connected to the municipal sewer due to the natural slope of the terrain.
Models | Phase | Power | Pipe Size (mm) | Start Method | Max. Solid size mm | Discharge in LPM | Total heads in metres | |||||||||
KW / HP | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 | ||||||||
SPDS 1050 | 1 | 0.75 / 1.0 | 50 | CAP | 25 | 260 | 215 | 180 | 130 | 65 | ||||||
SPDS 1550 | 1/3 | 1.10 / 1.5 | 50 | CAP/DIR | 25 | 290 | 280 | 260 | 190 | 130 | 80 | |||||
SPDS 2050 | 1/3 | 1.50 / 2.0 | 50 | CAP/DIR | 25 | 320 | 310 | 280 | 230 | 180 | 130 | 60 | ||||
SPDS 3050 | 1/3 | 2.25 / 3.0 | 50 | CAP/DIR | 25 | 330 | 320 | 300 | 270 | 220 | 170 | 110 | 50 |
Shallowell Jet Monoblock Pump
These Jet Monoblocks are compact pumping systems with the pump and motor mounted on a common shaft. The Jet Pump consists of a horizontal / vertical monoblock, jet unit and pressure valve which operates in combination to pump water from deep wells.
Models | Power | Pipe Size (mm) | Discharge in LPM | Total heads in metres | ||||||||
KW / HP | Suc x Del | 6 | 12 | 18 | 24 | 30 | 33 | 37 | 41 | |||
0.5 HP SWJP (AL/CI) | 0.37 / 0.5 | 25 x 25 | 49 | 44 | 42 | 38 | 35 | 17 | ||||
1.0 HP SWJP (AL/CI) | 0.75 / 1.0 | 25 x 25 | 52 | 50 | 47 | 44 | 38 | 28 | 16 | 05 |
Horizontal Multistage Openwell
A multistage pump operates by one impeller feeding into the next impeller and the number of impellers required depend on the discharge pressure requirement.
Models | Power | Stage | Pipe Size (mm) | Discharge in LPM | Total heads in metres | ||||||||||||||||
KW / HP | 3 | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 50 | 60 | 70 | 80 | 90 | 100 | 110 | 120 | ||||
5SPH-03-01 | 0.22 / 0.3 | 1 | 20 | 40 | 27 | ||||||||||||||||
5SPH-10-05 | 0.75 / 1.0 | 5 | 25 | 90 | 84 | 75 | 69 | 57 | 45 | 29 | |||||||||||
6SPH-05-05 | 0.37 / 0.5 | 5 | 32 | 102 | 93 | 83 | 71 | 61 | 41 | ||||||||||||
6SPH-10-07 | 0.75 / 1.0 | 7 | 32 | 102 | 96 | 88 | 80 | 75 | 65 | 41 | |||||||||||
6SPH-15-09 | 1.1 / 1.5 | 9 | 32 | 101 | 95 | 91 | 85 | 79 | 66 | 50 | 41 | ||||||||||
6SPH-20-14 | 1.5 / 2.0 | 14 | 40 | 98 | 94 | 92 | 90 | 83 | 72 | 69 | 64 | 57 | 33 |
Centrifugal Monoblock Pump
Centrifugal Monoblock Pumps are a popular type of water pumps used in India. They are installed on a dry surface protected from rainfall and operate and pump water from the source to the intended storage/usage through an electrical motor and pump connected vide a single shaft (monoblock).
Models | Power | Pipe Size (mm) | Discharge in LPM | Total heads in metres | ||||||||||||
KW / HP | Suc x Del | 08 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | 30 | 34 | ||
SPEL-01 | 0.37 / 0.5 | 25 X 25 | 135 | 130 | 120 | 87 | 52 | |||||||||
SPEH-01 | 0.37 / 0.5 | 25 X 25 | 120 | 113 | 99 | 84 | 54 | 18 | ||||||||
SPH-01 | 0.37 / 0.5 | 25 X 25 | 140 | 135 | 122 | 98 | 64 | 30 | 17 | |||||||
SPM-01 | 0.37 / 0.5 | 40 X 40 | 270 | 238 | 185 | 115 | ||||||||||
SPM-02 | 0.75 / 1.0 | 32 X 25 | 130 | 107 | 93 | 74 | 47 | 35 | 16 | |||||||
SPM-03 | 0.75 / 1.0 | 40 X 40 | 273 | 208 | 205 | 191 | 163 | |||||||||
SPM-04 | 0.75 / 1.0 | 50 X 50 | 390 | 348 | 213 | 152 | ||||||||||
SPM-06 | 0.75 / 1.0 | 80 X 80 | 780 | 660 | 390 | |||||||||||
SPM-18 | 1.1 / 1.5 | 50 X 50 | 442 | 360 | 274 | 168 | ||||||||||
SPM-31 | 1.1 / 1.5 | 80 X 80 | 561 | 462 | ||||||||||||
SPM-25 – 1P | 1.5 / 2.0 | 65 X 50 | ||||||||||||||
SPM-25 – 2P | 1.5 / 2.0 | 65 X 50 | ||||||||||||||
SPM-34 | 1.5 / 2.0 | 80 X 80 | 600 | 550 | 417 | |||||||||||
SPM-24 – 1P | 1.5 / 2.0 | 65 X 50 | 534 | 492 | 473 | 450 | 408 | 335 | ||||||||
SPM-24 – 2P | 1.5 / 2.0 | 65 X 50 | 534 | 492 | 473 | 450 | 408 | 335 |
V4 Submersible pump
A submersible pump, also called an electric submersible pump, is a pump that can be fully submerged in water. The motor is hermetically sealed and close-coupled to the body of the pump. A submersible pump pushes water to the surface by converting rotary energy into kinetic energy into pressure energy.
S.No | Model | HP | Stage | Del in MM |
1 | SPV4C4-0506 | 0.50 | 06 | 32 |
2 | SPV4C4-0508 | 0.50 | 08 | 32 |
3 | SPV4C4-0510 | 0.50 | 10 | 32 |
Total heads in Metres | |||||||||||||||||
0 | 8 | 10 | 15 | 20 | 22 | 26 | 28 | 32 | 24 | 35 | 39 | 43 | 47 | 50 | 55 | 60 | 64 |
90 | 85 | 80 | 70 | 65 | 60 | 55 | 48 | 35 | 20 | 5 | – | – | – | – | – | – | – |
75 | 70 | 65 | 60 | 55 | 53 | 48 | 45 | 42 | 40 | 38 | 35 | 28 | 5 | – | – | – | – |
65 | 62 | 60 | 58 | 54 | 52 | 50 | 48 | 45 | 43 | 40 | 35 | 33 | 25 | 20 | 10 | – | – |
S.No | Model | HP | Stage | Del in MM |
4 | SPV4C4-0708 | 0.75 | 8 | 32 |
5 | SPV4C4-0710 | 0.75 | 10 | 32 |
6 | SPV4C4-0712 | 0.75 | 12 | 32 |
7 | SPV4C4-0714 | 0.75 | 14 | 32 |
Total heads in Metres | |||||||||||||||||
0 | 10 | 15 | 21 | 25 | 28 | 31 | 34 | 39 | 43 | 48 | 51 | 54 | 60 | 65 | 74 | 77 | 84 |
90 | 85 | 80 | 75 | 70 | 63 | 60 | 55 | 40 | 35 | – | – | – | – | – | – | – | – |
75 | 72 | 68 | 60 | 58 | 55 | 50 | 46 | 45 | 40 | 33 | 31 | 25 | – | – | – | – | – |
75 | 70 | 65 | 57 | 55 | 54 | 50 | 48 | 46 | 44 | 42 | 4 | 35 | 31 | 25 | – | – | – |
65 | 62 | 60 | 58 | 56 | 55 | 52 | 50 | 48 | 45 | 43 | 41 | 39 | 33 | 25 | 15 | 10 | – |
S.No | Model | HP | Stage | Del in MM |
8 | SPV4C12-1004 | 1.00 | 4 | 50 |
9 | SPV4C10-1005 | 1.00 | 5 | 50 |
10 | SPV4C7-1006 | 1.00 | 6 | 40 |
11 | SPV4C5-1008 | 1.00 | 8 | 40 |
12 | SPV4C4-1010 | 1.00 | 10 | 32 |
13 | SPV4C2-1015 | 1.00 | 15 | 32 |
14 | SPV4C1-1018 | 1.00 | 18 | 32 |
Total Head In Meters | ||||||||||||||||||
0 | 14 | 17 | 19 | 21 | 24 | 26 | 30 | 34 | 38 | 43 | 55 | 64 | 68 | 77 | 85 | 99 | 108 | |
200 | 150 | 130 | 115 | 90 | 65 | – | – | – | – | – | – | – | – | – | – | – | – | |
175 | 145 | 135 | 130 | 120 | 100 | 95 | 60 | – | – | – | – | – | – | – | – | – | – | |
150 | 135 | 130 | 122 | 115 | 112 | 110 | 85 | 60 | – | – | – | – | – | – | – | – | – | |
130 | 120 | 110 | 105 | 100 | 95 | 92 | 85 | 80 | 60 | 45 | – | – | – | – | – | – | – | |
90 | 86 | 84 | 82 | 80 | 77 | 75 | 70 | 65 | 60 | 55 | 25 | – | – | – | – | – | – | |
75 | 70 | 68 | 66 | 64 | 62 | 60 | 58 | 56 | 53 | 51 | 45 | 40 | 35 | 30 | 15 | – | – | |
65 | 62 | 60 | 59 | 58 | 57 | 56 | 55 | 54 | 52 | 50 | 45 | 42 | 40 | 33 | 23 | 10 | – |
S.No | Model | HP | Stage | Del in MM |
15 | SPV4C12-1506 | 1.50 | 6 | 50 |
16 | SPV4C10-1507 | 1.50 | 7 | 50 |
17 | SPV4C5-1510 | 1.50 | 10 | 40 |
18 | SPV4C5-1512 | 1.50 | 12 | 40 |
19 | SPV4C4-1515 | 1.50 | 15 | 32 |
20 | SPV4C2-1520 | 1.50 | 20 | 32 |
Total Head In Meters | ||||||||||||||||||
0 | 15 | 20 | 26 | 28 | 30 | 36 | 43 | 48 | 51 | 60 | 64 | 77 | 85 | 94 | 111 | 118 | 132 | |
200 | 170 | 150 | 130 | 115 | 100 | 65 | – | – | – | – | – | – | – | – | – | – | – | |
175 | 155 | 140 | 130 | 125 | 120 | 95 | 25 | – | – | – | – | – | – | – | – | – | – | |
130 | 120 | 110 | 105 | 97 | 95 | 85 | 80 | 60 | 55 | – | – | – | – | – | – | – | – | |
130 | 115 | 105 | 100 | 95 | 92 | 90 | 86 | 82 | 80 | 55 | 45 | – | – | – | – | – | – | |
90 | 85 | 80 | 78 | 76 | 74 | 72 | 70 | 67 | 65 | 58 | 55 | 40 | 20 | – | – | – | – | |
75 | 70 | 68 | 65 | 62 | 60 | 58 | 56 | 54 | 52 | 50 | 48 | 43 | 40 | 35 | 25 | 10 | – |
S.No | Model | HP | Stage | Del in MM |
21 | SPV4C12-2008 | 2.00 | 08 | 50 |
22 | SPV4C10-2010 | 2.00 | 10 | 50 |
23 | SPV4C7-2012 | 2.00 | 12 | 40 |
24 | SPV4C5-2015 | 2.00 | 15 | 40 |
25 | SPV4C4-2020 | 2.00 | 20 | 32 |
26 | SPV4C2-2025 | 2.00 | 25 | 32 |
Total Head In Meters | |||||||||||||||||
0 | 15 | 20 | 26 | 34 | 37 | 43 | 48 | 51 | 60 | 64 | 75 | 85 | 90 | 106 | 118 | 132 | 150 |
200 | 170 | 160 | 155 | 130 | 115 | 90 | 65 | – | – | – | – | – | – | – | – | – | – |
175 | 155 | 150 | 145 | 135 | 130 | 120 | 105 | 95 | 60 | – | – | – | – | – | – | – | – |
150 | 140 | 135 | 130 | 125 | 122 | 115 | 112 | 110 | 85 | 75 | – | – | – | – | – | – | – |
130 | 115 | 110 | 103 | 100 | 98 | 95 | 92 | 90 | 83 | 80 | 55 | 30 | – | – | – | – | – |
90 | 85 | 82 | 80 | 78 | 75 | 72 | 70 | 68 | 65 | 63 | 60 | 55 | 50 | 35 | 10 | – | – |
75 | 70 | 68 | 66 | 64 | 62 | 60 | 58 | 56 | 54 | 52 | 50 | 46 | 44 | 40 | 33 | 30 | – |
Type | Flow Type | Motor | Pump | Volt & Hz |
V4 (92.5) | R : 20 FT / STAGE | BODY : SS | Bowl : Noryl | I – Phase 220 Volt , 50 Hz |
RADIAL FLOW | Rotor : Copper | Impeller : Noryl | III – Phase 415 Volt , 50 Hz |